| Specifications |
| Standard
Features |
| Optical modules |
100 MB/sec (1-Gbit/sec) full
duplex
Shortwave laser, module supports up to 500 meters
Long Wave GBIC - up to 10 km distance |
| Fiber cable |
50 micrometer multimode,
SC-type connectors
500 meters maximum length with Short Wave GBIC
10 km distance with Long Wave GBIC |
| RReliability,
Availability, Servicability |
| Redundancy |
FC-AL 7-port hubs
Dual FC-AL loops
Power supplies
Variable speed fans
Dual-port, FC-AL adapter
Interface boards |
| High availability |
RAID 0+1
Dual FC-AL loops
Dual-port, FC-AL drives
Dual-port, FC-AL adapter
Dynamic multi-pathing
Automatic loop failover |
| Online serviceable components |
DC power supplies
Variable-speed fans
Interface boards
Dual-port disk drives
FC-AL loops
FRU-level diagnostics and revision levels: host adapter, array interface,
disk drives, power supplies, port status, GBICS, interconnect |
| Configurations |
| Standalone |
22 hot-plug dual-port FC-AL
disk drives mounted front and rear
Three hot-plug, high reliability power supplies
Two variable-speed hot-plug fans with rotation and temperature sensors
Two hot-plug interface boards with up to two FC-AL 100 MB/sec GBIC modules
each
Electro-luminescent display panel with status displays for disk drives,
fans, fiber links, and power on self-test |
| Rack-mounted |
Up to six arrays (using 22-drive
enclosures), up to four FC-AL hubs, 2-m to 15-m fiber-optic cables, 72-in.
Sun StorEdge Expansion Cabinet with dual power sequencers |
| Host
System Interface |
| SBus card |
Single-width fibre channel
SBus card
Sun Serial Optical Channel ASIC
Up to two arrays per card |
| PCI bus card |
Single-loop fibre channel
PCI card, 32-bit 66-MHz PCI 2.1 |
| Fibre
Channel Interface Standards |
| Standards |
ANSI Fibre Channel FC-PH
X3230-1995
ANSI SCSI Fibre Channel Protocol X3.269-1996 |
| Optical modules |
100 MB/sec (1 Gb/sec) full
duplex
Shortwave laser, longwave laser GBIC |
| Fibre cable type |
50 micrometer multimode,
ST type connectors, 9 micrometer single mode |
| Maximum cable length |
500 meters multimode, 10
km single mode |
| Diskdrives |
| Form factor |
Low-profile 3.5-in. FC-SCA-2
with dual 100 MB/sec FC-AL ports |
| Interface |
Fibre Channel Arbitrated
Loop |
| Supported drives |
36.4 GB, 73.4 GB low-profile
10,000-rpm dual-port FC-AL |
| Host
Software |
| VERITAS Volume Manager |
Solaris(tm) Operating Environments
2.5.1, 2.6, 7, and 8 Included with array subsystem
X/Motif graphical user interface
Virtual storage management
Independent disks, volume concatenation
RAID levels 0 (striping), 1 (mirroring), 1+0 (mirrored stripes), and 5
(striping with rotated parity)
Online storage reorganization and load balancing
Visual performance displays for tuning
Complete status displays
Command line interface also provided
Dynamic multipathing for high availability and load balancing |
| Environmental
- Departmental |
| AC Power |
100-240 VAC, 47-63 Hz, 5
A at 200 VAC, 10 A at 100 VAC |
| Input Power |
650 W |
| Operating |
5C to 40C (50F to 104F)
20% to 80% relative humidity, noncondensing
27C (81F) maximum wet bulb
Altitude: 3 Km
Vibration: 0.2 G, 5 to 500Hz swept sine
Shock: 3-Gs, 11-ms half sine |
| Nonoperating |
-20C to 60C (-4F to 140F)
93% relative humidity, noncondensing
Altitude: 12 Km
Vibration: .8 G, 5 to 500Hz swept sine
Shock: 15-Gs, 11-ms half sine |
| Operating acoustics |
6.6 bels (at 25C/77F)
Declared noise emissions in accordance with ISO 9296 |
| Heat output |
2,220 BTU/hr. maximum |
| Airflow clearance |
6.0 in. (15.24 cm) all sides |
| Regulations
- Departmental |
| Meets or exceeds
the following requirements |
| Safety |
UL 1950, CSA 950, TUV EN
60950
Class 1 laser requirements per CFR 21, Part 1040 and IEC 825 |
| RFI/EMI FCC |
FCC Class A, DOC Class A,
VCCI Class 1, EMC Directive (89/336/EEC), EN55022 |
| Immunity |
EMC Directive (89/336/EEC),
EN55082-1 |
| Harmonics |
EMC Directive (89/336/EEC),
EN60555-2 |
| Dimentions
and Weight - Departmental |
| Height |
22.7 cm (9.01 in.) |
| Width |
49.5 cm (19.65 in.) |
| Depth |
62.5 cm (24.81 in.) |
| Weight (without drives) |
35 kg (79 lb.) approx. |
| Weight (with drives) |
54 kg (120 lb.) approx. |
| Power cord |
1.83 m (6 ft.) |
| Environment
- Data Center |
| AC Power |
200 to 240 VAC
47 to 63 Hz
24 amps |
| Input Power |
3900 W |
| Operating |
5C to 35C (50F to 95F)
20% to 80% relative humidity, noncondensing
27C (81F) maximum wet bulb |
| Nonoperating |
-20C to 60C (-4F to 140F)
93% relative humidity, noncondensing |
| Operating acoustic noise |
8.0 bels (at 25C/77F)
Declared noise emissions in accordance with ISO 9296 |
| Heat output |
13,320 BTUs/hr maximum |
| Airflow clearance |
51 cm (2 in.) left, 0 right,
61 cm (24 in.) front and rear |
| Regulations
- Data Center |
| Meets or exceeds
the following requirements |
| Safety |
UL 1950, CSA 950, TUV EN
60950
Class 1 laser requirements per CFR 21, Part 1040 and IEC 825 |
| Complies with
the following when installed in a Sun data center cabinet |
| RFI/EMI |
FCC Class A, DOC Class A,
VCCI Class 2, EMC Directive (89/336/EEC), EN55022 Class B |
| Immunity |
EMC Directive (89/336/EEC),
EN55082-1 |
| Harmonics |
EMC Directive (89/336/EEC),
EN60555-2 |
| Dimentions
and Weight - Data Center |
| Height |
187 cm (73.5 in.) |
| Width |
61 cm (24 in.) |
| Depth |
93 cm (36.5 in.) |
| Weight (with six full
arrays) |
394 kg (867 lb.) approx.
maximum |
| Power cord |
4.6 m (15 ft.) |