| Specifications |
| Capacity
and Performance |
| |
6910 |
6960 |
| Drives |
Dual-ported
10K RPM FC-AL
FS-SCA-2 (3.5-in.) |
Dual-ported
10K RPM FC-AL
FS-SCA-2 (3.5-in.) |
| Power receptacles required |
(US) Two NEMA
per cabinet L6-30P for 200-240 VAC
(International) Two 32A, single phase IEC 309 connected to 220-240 VAC |
(US) Two NEMA
per cabinet L6-30P for 200-240 VAC
(International) Two 32A, single phase IEC 309 connected to 240-240 VAC |
| 36 GB drives |
1.9 TB max
cabinet (54 drives) |
1.9 TB max
cabinet (54 drives)
5.2 TB max system (total of 144 drives with expansion cabinet) |
| 73 GB drives |
3.9 TB max
cabinet (54 drives) |
3.9 TB max
cabinet (54 drives)
10.9 TB max system (total of 144 drives with expansion cabinet) |
| Logical Device Support |
1 - 256 LUNs |
1 - 512 LUNs |
| 36 GB drives for RAID
5 with Hot Sparing |
1.5 TB max
cabinet |
1.5 TB max
cabinet
4.0 TB max system |
| 73 GB drives for RAID
5 with Hot Sparing |
3.0 TB max
cabinet |
3.0 TB max
cabinet
8.2 TB max system |
| Configurations |
| Operating
system |
Solaris[tm] 8
Operating Environment
Microsoft Windows NT 4.0 (SP6)
Microsoft Windows 2000 Advanced Server (SP2) |
| Software |
| Supported
software |
Sun StorEdge
Availability Suite software
Sun StorEdge Utilization software
Sun StorEdge Performance Suite software
Sun StorEdge Resource Management Suite software
Solstice DiskSuite[tm] 4.2.1 software
VERITAS Volume Manager 3.2 software
VERITAS NetBackup 3.4 software
Solstice Backup[tm] 6.0 software, or later
Sun Cluster 3.0 update 2 software
VERITAS Cluster Server 2.0 software |
| Hardware
Platforms |
| Supported
hardware |
Sun Enterprise[tm]
10000 server
Sun Enterprise 3500, 4500, 5500, 6500 server
Sun Fire[tm] 280R, 3800, 4800, 4810, 6800 server
Sun Enterprise 220R, 250, 420R, 450 server
Intel Pentium III or higher (Microsoft Windows NT, Microsoft Windows 2000)
|
| Host
Connectivity |
| Supported
host bus adapters |
Sun StorEdge
PCI single fibre channel network adapter
Sun StorEdge PCI dual fibre channel network adapter
Sun StorEdge cPCI single fibre channel network adapter
Sun StorEdge cPCI dual fibre channel network adapter
QLogic 2200F/66*
Emulex LP8000-F1/N1* |
| Note: *Qualified
for Windows NT and Windows 2000 environments; supported by third-party
vendor. |
| Integrated switches |
Dual fibre channel
switches |
| Host connect |
F port (Fabric
Port) |
| Maximum Hosts |
6910 |
6960 |
| 7 |
14 |
| Environment |
| AC power |
200-240 VAC @
47-63 Hz single phase |
| |
6910 |
6960 |
| Heat output maximum |
~14,000 BTU |
~14,000 BTU |
| Note: ~26,000
BTU for 6960 system with expansion cabinet |
| Temperature-operating |
5º C to
35º C (41º F to 95º F) |
| Temperature-nonoperating |
-20º C to
60º C (-4º F to 140º F) |
| Shock-operating |
4.0 g for maximum
duration of 11 ms (half-sinewave) |
| Shock-nonoperating |
10.0 g for maximum
duration of 11 ms (half-sinewave) |
| Vibration-operating |
5 to 500 Hz @
0.25 g sinusoidal |
| Vibration-nonoperating |
5 to 500 Hz @
1.0 g sinusoidal |
| Humidity-operating |
20% to 80%, RH,
noncondensing, max gradient 10% per hour |
| Humidity-nonoperating |
5% to 93%, RH,
noncondensing, max gradient 10% per hour |
| Altitude-operating |
-1000 ft. to
+ 10,000 ft. (-305 m to 3048 m) |
| Altitude-nonoperating |
-1000 ft. to
+ 40,000 ft. (-305 m to 12,192 m) |
| Regulations |
| Meets or exceeds
the following requirements: |
| RFI/EMI |
FCC Class A |
| Safety |
UL/CSA, CE, FC-AL
standards |
| Dimensions
and Weight |
| |
6910 |
6960 |
| Height |
1905 mm (75 in.) |
1905 mm (75 in.) |
| Width |
607.1 mm (23.9 in.) |
1214.1 mm (47.8 in.) |
| Depth |
939.8 mm (37 in.) |
939.8 mm (37 in.) |
| Weight |
549 kg (1210 lb.) |
1314 kg (2895 lb.) |