| Specifications |
| Processor |
| Number of
processors |
Up to 36 |
| Architecture |
UltraSPARC
IV & UltraSPARC III ECC-Protected Processors |
| Cache per
Processor |
Level 1:
Parity-Protected 64KB Instruction and 128KB Data on Chip (Single Bit
Errors are Corrected)
Level 2: ECC-Protected 16 MB
External Cache |
| System
Interconnect |
150 MHz Sun
Fireplane Redundant Data, Address, and Response Crossbar Interconnect |
| System |
| Main Memory |
Up to 288
GB Memory per Domain with End-to-End Data Integrity |
| CPU/Memory
Boards |
Up to 9 Uniboard
CPU/Memory boards with 4 Processors Each, and up to 32 GB per board. |
| I/O |
Up
to 36 I/O hot-swap PCI+ I/O slots; 27 slots are 66/33 MHz, 9 slots
are 33 MHz
Supports 10/100Base-T Ethernet, Gigabit
Ethernet, UltraSCSI (LVD & HVD), ATM, HIPPI, & FC-AL |
| Performance |
| Overall
System Bandwidth |
Up to 86.4
GBps Aggregate; Up to 57.6 GBps Peak; Up to 12.6 GBps Sustained.
|
| Overall
I/O Bandwidth |
Up to 12.6
GBps Sustained. |
| Availability |
| |
Hot CPU Upgrades
Hot-Swap
CPU, Memory, I/O, Power, Fans
Online upgrades
Journaling file system
Redundant network connections
Redundant storage connections
Hardened operating system kernel
Hardened I/O drivers |
| RAS
Features |
| DR/ADR |
Dynamic
Reconfiguration: Concurrent DR; initiate DR from domain, as well as
from System Controller (SC) |
| Dynamic
System Domains |
Up
to 9 fifth-generation, fault-isolated Dynamic System Domains, Dynamic
Partitioning |
| Security |
| Dedicated
network connections (System Controller to 9 domains) inside the Sun
Fireplane interconnect |
| Resource
Management |
| Sun's
fifth-generation Dynamic System Domains, Solaris Resource Manager[tm]
software, and Solaris Bandwidth Manager software |
| Software |
| Operating
system |
Solaris
8 Operating Environment (02/04)
Solaris
9 Operating Environment (04/04 or Later) |
| Languages |
C, C++, Pascal,
Fortran, Java technology |
| Networking |
ONC/NFS,
TCP/IP, SunNet OSI, X.25 Start, DCE, Novell NetWare |
| System Management |
Sun
Management Center (SunMC) 3.5 Version 4; SMS 1.4.1 (or Later) |
| Network
Management |
VERITAS Volume
Manager 3.1.1,
VERITAS File System 3.4, Sun Cluster 3.0
|
| Mass
Storage |
| |
120+ TB direct
connect storage--Fibre Channel (1 GB and 2 GB) and UltraSCSI; Sun
StorEdge 9900, S1, D240, Sun StorEdge 6x00, and Sun StorEdge 3x00.
Direct attach to Sun StorEdge tape libraries and disk arrays, including:
Sun StorEdge 3000, 6000, and 9900, providing excellent linear scalability.
|
| Environment |
| AC power |
200-240 single-phase
VAC, 47-63 Hz. Two N+1 power grids, each using six 30-Amp circuits.
Second power grid provided for redundancy.
|
| Operating |
Optimum: 22° C (72° F) at 45% non-condensing
humidity
Range: 10° C to 35° C (50° F to 90°
F) at 20% to 80%
non-condensing humidity
Altitude: Up to 3048 m (10,000 ft.)
|
| Dimensions
and Weight |
| Height |
191 cm (74.75
in.) |
| Width |
85 cm (33.25
in.) |
| Depth |
166 cm (65
in.) |
| Weight |
987 kg (2,141
lb.) fully configured |
| Remote
Services |
| Sun
Remote Services Net Connect
Storage Automated Diagnostic Environment
CPU Diagnostics Monitor |
| Upgrades |
|
The Sun Upgrade Advantage Program (UAP) offers trade-in value for qualified
Sun and competitive servers towards the purchase of replacement Sun
Fire 12K servers. Whether upgrading one system or consolidating many
systems to one, Sun UAP offers the flexibility to trade-in systems and
receive credit towards the new Sun system purchased. Upgrades are also
available for Sun Fire server system component upgrades including CPU/memory
boards, and I/O assemblies. |